Installation guides and catalogues
Installation method statements, certificates and declarations of conformity, catalogues and system presentations. Every document opens straight from here — no sign-up, no requests.
Document language
Document type
Showing 26 documents of 94
Installation guides
- PDFT‑profilesENEight installation schemes with material consumption per 1 m².Download ↓
- PDFCube-shaped railENTraverse mounting, rail pitch, jointing and perimeter finishing.Download ↓
- PDFPlate-shaped railENScreen ceiling: load-bearing traverse, radius bending, smooth forms.Download ↓
- PDFClassic open cellENCell assembly, hangers, perimeter cutting.Download ↓
- PDFPyramidal open cellENInclined profile features and volumetric structure assembly.Download ↓
- PDFGLK cassette open cellENCassette system: laying into T‑profile grid, plenum access.Download ↓
- PDFDiagonal open cellEN45° layout, jointing and perimeter cutting.Download ↓
- PDFKRAFT LEDENCompatibility matrix of ceiling systems and fixture types, wiring diagram.Download ↓
- PDFWoodAcoustic — frame mountingENAcoustic panels on metal profile or wooden battens.Download ↓
- PDFWoodAcoustic — adhesive mountingENFor walls where ceiling height cannot be reduced.Download ↓
Certificates, declarations and test reports
- PDFKRAFT Nova T‑24 main runnerPLDeclaration of performance under Regulation (EU) 305/2011, PN‑EN 13964:2014‑05.Download ↓
- PDFKRAFT Fortis T15 / T‑24 main runnerPLDeclaration of performance covering both sizes.Download ↓
- PDFW-shaped wall anglePLDeclaration of performance for the wall angle.Download ↓
- PDFL-shaped wall anglePLDeclaration of performance for the shadow-line wall angle.Download ↓
- PDFOpen cell system hangerPLDeclaration of performance for the open cell hanger.Download ↓
- PDFLinear ceiling system hangerPLDeclaration of performance for the linear ceiling hanger.Download ↓
- PDFT-profile system hangerPLDeclaration of performance NR.11/2025/KRAFT, load 274 N and 161 N.Download ↓
- PDFMetal tilesPLDeclaration of performance for 600×600 and 1200×600 mm tiles.Download ↓
- PDFClassic open cell profilePLDeclaration of performance for the classic open cell grid.Download ↓
- PDFPyramidal open cell profilePLDeclaration of performance for the pyramidal open cell grid.Download ↓
- PDFCube-shaped profilePLDeclaration of performance for the cube-shaped linear ceiling.Download ↓
- PDFKRAFT LED light fittingsPLEC Declaration of Conformity No 01/2025, directives 2014/30/EU and 2014/35/EU.Download ↓
Catalogues and albums
Installation videos
Step-by-step installation videos for KRAFT systems
Diagonal open cell
T-grid ceiling
Cube-shaped linear ceiling
Cassette ceilings
Flexible traverse · installation
MESH HOOK-LOCK
MESH HOOK-LOCK Corridor
MESH CLIP-IN
MESH CLOUD
Life hack: T-grid into open cell
Installation FAQ
For the most common layout with a 600×600 mm tile: 0.232 main runners of 3600 mm, 1.4 cross tees of 1200 mm, 1.4 long tees of 600 mm, 0.7 hangers and 2.78 tiles per square metre. Schemes with a higher load rating double the number of main runners and hangers. The full calculation for every scheme is in the T-profile installation guide.
Hangers are spaced at 1200 mm along the main runner, with the first no more than 600 mm from the wall. On schemes with additional hangers the spacing is reduced — exact figures are in the consumption table.
An angle L profile 24×19 mm or a wall W profile 28×30 mm, 3000 mm long. The L profile is simpler to install; the W profile gives a closed edge and a neater junction with the wall.
No. The grid clips together: main runners connect to cross tees without any metal-cutting tools. Cutting is only needed around the perimeter. That removes wet trades and curing delays from the programme.
The minimum drop is 120 mm. The actual drop is set by the services: ventilation, cable trays, sprinklers. Baffle systems with integrated lighting need extra space for the luminaire.
Two ways. On a frame — metal profile or timber battens, the standard option for ceilings. Bonded — when height cannot be lost, mostly for walls. Both instructions are available for download above in four languages.
KRAFT profiles are tested by Instytut Techniki Budowlanej, EU notified body No. 1488. Declarations of performance have been issued under Regulation (EU) No 305/2011 to the harmonised standard PN‑EN 13964:2014‑05, with Euroclass A1 reaction to fire — non-combustible. Alongside these are test reports for sound absorption and fire safety.
Can't find the document you need?
Send a request — we will prepare a specification, a bill of materials or a document for your tender.
Send a request